Replace SSDs
Replace SSDs
Replacing Failed SSD Drives:
-
Identify and Replace Failed SSDs
- Type show-ssds to see the status of the drives
1. record the index and brick numbers of the failed drive
-
Issue the remove-ssd ssd-id=\
1. Physically replace the failed ssd
- Type show-ssds to show uninitialized ssd drives
1. NOTE: record the complete wwn and index number of the new drive
- If drive does not show up in show-ssds, run show-slots and verify the status of your drive.
- Type add-ssd brick-id=brickid ssd-uid="wwnid"
1. If the disk was previously used in another XtremIO you may get an error about foreign_xtremapp_ssd. If you do add the following to the end of the add-ssd command is-foreign-xtremapp-ssd
1. Type assign-ssd dpg-id=id# ssd-id=id#
Examples
remove-ssd ssd-id=34
add-ssd brick-id=2 ssd-uid="wwn-0x5000cca02b241ff8"
assign-ssd dpg-id=2 ssd-id=51
- Type show-ssds to see the status of the drives
- Replace the failed ssd
- Issue the replace-ssd ssd-id=\
- Type show-ssds to verify replacement