Chassis Replacement
If the whole chassis has been replaced then we need to set the service tag as well as setting the midplane serial number.
Setting the service tag
Log into the system [[General Information - SVC30x0]]
Elevate privileges
shellaccess developer
Set the service tag for the replacement chassis and ssn for midplane
platform bmc fru set 2 service_tag <service tag number>
platform bmc fru set 2 ssn <top controller ssn>
platform bmc fru set 3 service_tag <service tag number>
platform bmc fru set 3 ssn <top controller ssn>
Check that the service tag and ssn have been updated
platform bmc fru display_all 2
platform bmc fru display_all 3
Reset both controllers, starting with the top controller first
-reset
Note
Issue seen where a complete system reboot was needed to bring the system up correctly
Complete manual [[SC Series_SC3020 Replacement-Storage System Chassis.pdf]]