Dell Compellent Controller Replacement
PRODUCTS AFFECTED
Compellent models prior to SC8000 in which the whole chassis is the controller
Considerations
- Older, single system board models will require an outage for replacement
- The old drive MUST be moved over to the new system board/controller before replacement
PROCEDURES
- Remove the failed controller
a. On older models, the Compellent system board may be failing, but still online. If this is the case, perform a clean shutdown - Identify the location of the SSD on the old Controller or System Board
- Remove the SSD by releasing any retainer screws and pulling the drive out
- Install the SSD into the replacement Controller or System Board
a. Note: If there is already a drive in the replacement, DO NOT USE IT IN THE CUSTOMER SYSTEM - After installing the replacement Controller or System Board, the system will perform multiple reboots while it updates code. During this time, do not power the system offline.
a. Note: All network cables must be plugged in before the system will bring a replacement controller online