Technical Knowledge Base

Replace SC Disk

Replace SC Disk

Replacing a failed Local Disk ( Disk in the Storage Controller)

  1. From the cli as the user tech, type the following command to display failed storage controller local disk:
show-local-disks
  1. Once you have located the failed local disk, physically replace the disk
  2. After the disk is replaced
replace-local-disk locak-disk-id="<localdiskname>"

Example: replace-local-disk local-disk-id="X2-SC2-LocalDisk5"